Shutters Hardware Installation - Classic Shutters Collection |
|
Storm Rated Installation Instructions |

L-Hinge |

Flat Hinge |

Carriage Bolt and Square Nut |

L-Hinge Backer Plate |

Flat Hinge Backer Plate |
|
|
For varying heights of shutters, use the following quantities of
hinges per shutter:
Height from 12" to 48", Two hinges per shutter
Height greater than 48" to 76", Three hinges per shutter
Height greater than 76" to 102", Four hinges per shutter
L-Hinges and Flat Hinges are the only approved hardware for
storm rated mounting. L-Hinges are typically
used at the top and bottom of the shutter. Flat Hinges are used
between L-Hinges when 3 or 4 hinges are
needed.
The L-Hinge is shown for instructional purposes. If a Flat Hinge
is being used, follow the same installation
methods. |
Classic shutters Collection Mounting Instructions
|
|
1. Measure and mark hinge locations as shown. The top and bottom hinges are typically placed
1" from the ends of the shutter. |
 |
|
2. Align the hinge to the outer edge of the shutter and to one of the marks previously measured. If
a Polycarbonate Mounting Screw is in the way, remove it. |
 |
|
3. Using the hinge as a template, drill 1/4" holes through the shutter. Make sure the drill bit is
square to the shutter in all directions. The holes MUST be drilled straight. |
 |
|
4a. Place the Backer Plate on the non-polycarbonate side of the shutter and insert the Carriage Bolts. |
 |
4b. Attach the hinge to the polycarbonate side of the shutter using the Square Nuts.
5. Repeat steps 2-4 for the remaining hinge(s).
6. Repeat steps 1-5 for the other shutter. Make sure to attach hinges to the opposite edge of the
shutter as the first. This creates a left and right shutter. |
 |
Pintel Mounting Instruction
- EXISTING STRUCTURE MAY BE CONCRETE, HOLLOW BLOCK OR WOOD
FRAMING FOR PROPER ANCHOR
TYPE BASED ON TYPE OF EXISTING STRUCTURE, SEE ANCHOR SCHEDULE
BELOW.
- ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS.
- WHERE EXISTING STRUCTURE IS CONCRETE OR HOLLOW CONCRETE BLOCK,
MINIMUM EDGE DISTANCE
SHALL BE 3" FOR ALL ANCHORS.
- WHERE EXISTING STRUCTURE IS WOOD FRAMING, EXISTING CONDITIONS
MAY VARY. FIELD VERIFY THAT
FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD.
- MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO OR OTHER
EXTERIOR WALL FINISHES.
ANCHOR SPECIFICATIONS
HINGE PINTEL ALLOWABLE ANCHORS:
TO CONCRETE: 3" FASTENER EDGE DISTANCE - 3/16" x 1 3/4" EMBED
TAPCON OR EQUIVALENT
TO WOOD: 3/4" FASTENER EDGE DISTANCE - #10 x 1 3/4" EMBED WOOD
SCREWS OR EQUIVALENT |
|
1. Hold the shutters in place in the window opening. Using shims, position the shutter in
the opening to create an 1/8" gap around the top, bottom, and hinge side of the shutter.
This is only necessary when mounting the shutter in an opening. The 1/8" gap does not
apply for overlap conditions. |
 |
|
2. Identify the locations of the Pintels on the wall and mount each Pintel pointing in the
upward position, except for the bottom pintel. See anchor specifications above for correct
fastener. |
 |
3. Mount the bottom Pintel in the downward position. See anchor specifications above for correct fastener.
Mounting the bottom Pintel in the downward position prevents the shutter from lifting off.
 |
|
4. If Flat Hinges (not shown) are used between L-hinges, the corresponding Pintels should point
upward. Once all the Pintels have been fastened to the wall, remove the shims. |
 |
|
5. Repeat steps 1-4 for the shutter on the opposite side. |
 |
 |